Our Team Size
MR. TASNEEM MR. HAKEEM MR. IMRAN AHMED Helpers
Chief Engineer with 12 years
Experience in Handling
Major Electrical installation.
Qualification B.E. (Elec)
Engineer with 6 years
Experience in Handling
Major Electrical installation.
Qualification B.E. (Elec)
Foreman with 5 years
experience.
Skilled Electricians 15 persons
Skilled Helpers 10 persons
Unskilled Helpers 8 persons

 

I. HT (High Tensions)- 11 kv

  1. Installations of RCC poles RSJ/Tabular poles with GOS, HORN GAP Fuse cross arms, pin insulators, guysets, conductor, stringing of conductors, chainlink fencing, complete as required by E.B.

  1. Installation of double pole structure with metering cubicle.

  1. Installation of four poles structure with metering cubicle.

  1. Installation of HT metering cubicle with or without incoming isolator.

  1. Incoming isolator ring mains unit with loop in and out isolator and outgoing isolator with HRC fuse and HT metering cubicle and HT cabling.

  1. HRC Fuse Ringmain unit with loop in isolator and outgoing 11kv breaker and HT metering cubicle total substation with distribution transformer.

  1. Approvals: Inspection and testing of HT Installation from Department of Electrical inspectorate.



II. LT (Low Tension) 11kv / 433v

  1. Installation of RCC/R.SJ/Tabular poles with cross arms Pin insulator, guysets, ACSR conductors, stringing for LT-433v completed as required by E.B.

  1. Installation of 11/433 V Distribution Transformer Indoor / Outdoor with all required protection as required by E.B.

  1. Installation of 433 KV motor control centers, panels for distribution of lighting and power requirements.

  1. Capacitor panels automatic / manual as it is required from Electricity Supply authority to maintain a power factor or not less than 0.90F.

  1. Approval Inspection and Testing LT Installation from Department Electrical Inspectorate.



2. PANELS & DISTRIBUTION BOARDS (IS-2675 OR BS-214)

  1. Fabrication & Installation of panels with 16 swg CR Sheet Steel with M/c pressing, treated for derusting atleast 3 tank process with dephosphating and painting with atleast 2 coats of approval dust and vermin proof paint and stoving in Electric Chamber / power coating.

The Panel fabricated shall be totally enclosed metal clad type with double gasketing with rubber / resin lining with control direction poster inside the panel.

The panel shall be utilized for Motor Control, Pumps Lighting & Distribution, Capacitor Control Lifts, Emergency Lighting, D.G Sets AMF Kitchen Equipments, A/c Installation, Computer / UPS Installation and various other Installations.


3. WIRING

  1. Medium Voltage distribution system at 3 phase 4 wire 415v, 50Hz and single phase 2 wire 240v 50Hz A/c supply.

  1. Installation of open / surface conduit system, Recessed conduit system, Conduits above fall ceiling PVC or MS Conduits with all accessories like bends collars, junction Boxes Pull boxes etc.

  1. Wiring conductor of PVC insulated, FRLS, FR (FIRE RETARDENT LOW SMOKE) of stranded aluminium or Copper Conductor of 660v gade as per IS 694 Part 11 (Latest Edition) in Red, Yellow, Blue and Green as earthing shall be used in submains wiring, Circuit wiring with PVC identification ferrules at either and bearing the circuit number and designation fro lighting and power circuits with switch sockets and accessories, Industrial type sockets, Lampholders, Ceiling rose fans and fixtures Testing of electrical Installation as per Is-732-1963, Testing at earth continuity path, Polarity of non linked single pole switch, sockets and regulators as per IS and BIS codes (IS 732-1982)

  1. LT Cabling considering the conditions of maximum connected load, ambient temperature, grouping factor, allowances for voltage drops of PVC insulated, armoured laid in outdoor trenches, End terminated using brass single or double compression glands with Copper / Aluminium lugs including Testing and Commissioning as per IS-1554 par-1.

  1. Earthing Electrodes as per IS-3943 Compressing of Allu / Copper Plate Electrode and GI Pipe Electrode.




4.CAPTIVE POWER GENERATION

  1. D.G. sets: Diesel Generation invariably constitute an integral part of an Electrical Installation either industrial or a multistoried building or Residential apartment.

    Installation, Testing, Commissioning of DG sets with Sizing, Ventilation system and earthing with all safety standards.

    Obtaining necessary approval from electrical Inspectorate.

  1. Cooling system of Generators, erection and Commissioning of remote radiators, heat exchangers, Cooling towers etc.


5. ELECTRICAL CONSULTING

  1. Total Project Management

  2. Preparing Electrical layout drawing,Electrical load list ,Single line diagram of Electrical loads

 

            TARGET SECTORS
  1. Residential Houses, Apartments, Serviced apartments etc.

  2. Commercial complexes, Shopping Malls; Shops, Offices, showrooms, Banks etc.

  3. Hotels: Fast Food Restaurants, 3 star and 5 star hotels, Resort Amusements parks.

  4. Hospitals: Specially and super specialty Hospitals, Clinics, Labs etc.

  5. Educational Institution: Colleges, Schools of Engineering and Medical.

  6. Industries: Heavy and Light Industries.